Saturday, March 4, 2017

CEWE ELITE 440 - MULTI LINE 3 PHASE PANEL METER

ELITE 440 - CEWE INSTRUMENT



Elite 440 is a multi-line three-phase digital panel meter for accurate and reliable measurement of electrical  parameters (voltage, current, power, frequency, etc.) for industrial and commercial applications. It has a large multi-line backlit LCD display which enables four parameters to be displayed at the same time.  Modbus communication capability allows easy integration with energy monitoring systems. Expansion modules can be fitted for enhanced system integration (pulse inputs/outputs or analogue output and ethernet).


Applications

1  Commercia an industrial  sub-metering  an energy management (EMS) applications.
2  Building management and monitoring systems  (BMS)
3  High, medium and low-voltage switchgear panels
4  Control and relay panels
5  Power Control Centre (PCC) panels 
 Motor Control Centre (MCC) panels 
 Relaying and control outputs
 Plant automation and monitoring system (SCADA/DAS)

Benefits
Easy interface with external devices through built-in Modbus
(RS-485/Ethernet)
 Detachable connectors for easy installation
 Diagnostics assistance on display
 Suitable  for star  or delta  connections and  for low or high- voltage applications
 Cost-effective online monitoring
 Field-configurable CT/PT primary and secondary values using push-buttons

Features
  Large four-line  seven-digit display  (9.7 H x 5 W mm) with quadrant identification section  and  bar  graph  for instantaneous power-level indication
 High accuracy: Class 0.2s, 0.5s, 1.0
 Average THD measurement for voltage,  current and  power, up to 31st harmonic
 Measurement selection (star or delta/ 3P4W or 3P3W)
5   Modbus communication via RS-485 port/ethernet
6   True root-mean squared (RMS) metering
7   Calibration LED for accuracy test on site
8   Wide and configurable current range 1-2A and 5-10A
9   Wide-range auxiliary power supply, suitable for high-voltage or low-voltage installations
10   Maximum demand recording
11   Midnight snapshot ( values) for selected energy registers
12   Scroll-lock and 'Favourites Page' display support
13   Expansion  capability  via  add   on  modules  for  analogue outputs or pulse inputs/outputs and ethernet
14   Password protection for setup mode
15  Ethernet gateway  module  for easy  integration of multiple meters connected over RS485 network

Note:
Ethernet (add on) module is available for all ELITE 440 models as single meter module or gateway. Additional modules (Two pulse input & output or four analogue outputs) can be available in ELITE 443 to ELITE 448.  #Optional software config view is available for reading and configuration.

WIRING DIAGRAM :


    MECHANICAL DIMENSION :
    TECHNICAL SPESIFICATION :
   Electrical
Connection type                  Common product for HT3/ HT4/ LT4 application
Voltage range :
Measurement voltage range                                    57.7 V (100V) - 240 V (415 V) AC 3 phase  4 wire (3 phase  3 wire)
Tolerance                                  -30% to +20% of Vn
Aux power supply range                                       80 - 300 V AC/DC or 24 - 60 V DC (Variant)
Current range                                                           Available 1-2A and 5-10 A in single variant (field configurable) 
Main frequency                                     50/60Hz with ±5%
Accuracy Class                                                        0.2s, 0.5s, 1.0
Burden                                                                      Aux burden : 3.5 VA; 8VA when all modules connected.
                                                                                       Current ckt burden : 1 A - 0.05VA per phase, 
                                                                                 5 A - 0.25 VA per phase. Voltage ckt burden : 0.15 VA per phase.
Short time over current                                           20 x I for 1 sec., 10 x I for 3 sec., 7 x I for 10 sec.

   

1 comment:

  1. hi I am Dina, In our site we are using Elite 440 energy meter.. And we connect the Elite meter modbus and checked. But we havn't read the modbus data from meter. Its seems the meter modbus is not configured. PLs advise how to mapping the modbus for elite 440.
    thanks

    ReplyDelete